Filters

DIRIN 230 ABEK2 HG P3 RD

Designed for Military, Law Enforcement and First Responders, the DPI Leonardo DIRIN 230 NBC A2B2E2K2HgP3 Filter is a critical asset when attending known or potential NBC incidents.

FEATURES

  • Casing: synthetic resin with high mechanical strength.
  • Filter material: activated carbon and filter paper.
  • Weight: <287 grams
  • Storage time: 5 years (in original packaging) or 10 years (in polybag packaging).
  • Packaging: Complete with plastic cap on spout and bottom. Single package. Dim. 98x98x98 mm.
  • Durability: Filter complying with the provisions of Regulation (EU) 2016/425. Combined class 2 filter for the gas part and class P3 R D filter for the dust part according to UNI EN 14387:2008.
  • Reference standard: EN 14387:04/A1:2008
  • Storage conditions: In original packaging Temperatures between -2 °C and + 55 °C Humidity at < 75%.
  • Marking:
    The R marking indicates that the filter is reusable for multiple shifts.
    The D marking indicates that the filter has passed the optional clogging test and is suitable in very dusty environments.
  • Limitations on Use: Do not use in environments with oxygen concentration less than 18% by volume and in the presence of gases and/or vapors other than those expressly indicated.

Manufacturer Website

DIRIN 230 NBC A2B2E2K2 HG P3

Designed for Military, Law Enforcement and First Responders, the DPI Leonardo DIRIN 230 NBC A2B2E2K2HgP3 Filter is a critical asset when attending known or potential NBC incidents.

With an NBC A2B2E2K2HgP3-level combined filter element surpassing EN 14387 requirements, it achieves unparalleled performance, defending against Sarin and related CWAs, Tear Gasses, Organic TICs, Inorganic TICs, Acid TICs, Ammonia and Amine gases, Mercury, Dusts, Mists, Fumes, Biological Agents (including Bacteria, Viruses, and Fungal Spores), and Radioactive Dusts. Tailored for tactical operations, the DIRIN 230 NBC A2B2E2K2HgP3 Filter seamlessly integrates with gas masks for a secure fit in today’s challenging environments.

FEATURES

• Filter connection: STANAG 4155 (EN 148-1) – Rd 40×1/7” threaded connection;
• Compatible masks: M21, C21 and IDEA CBRN full face masks;
• Weight: 290 g. ± 5%;
• Dimensions: Height included thread 90mm, diameter 90mm;
• Shelf life: 6 years – 10 years vacuum sealed version;
• Materials: Resistant and anti-scratch high-quality ABS resin;
• Filtering materials: Activated carbon and filter paper;
• Packaging: Complete with 2 plastic covers, on both threaded connector and filter bottom. 1 piece, packed in a carton box 98mm x 98mm x 98mm;
• Conditions of storage: In original packaging: Temperature between -2°C and +55°C RH <75%;
• Marking:
›› Marking R means the filters can be used for more than one shift of work;
• Limitations for use: Do not use in areas where the oxygen concentration is lower than 18% in volume nor in presence of gases different from those clearly indicated.

RIOT-C2 CS/CN/OC

The DPI Leonardo Riot-C2 Filter meets NIOSH 42CFR84 relevant criteria, ensuring optimal removal efficiency of CS/CN AGENTS and continuous 24-hour protection. With an A2P3-level combined filter element surpassing EN 14387 requirements, it achieves unparalleled performance, defending against OC (Pepper Spray), Organic TICs, Dusts, Mists, Fumes, Biological Agents (including Bacteria, Viruses, and Fungal Spores), and Radioactive Dusts. Tailored for Riot Control tactical operations, the Riot-C2 Filter seamlessly integrates with gas masks for a secure fit in today’s challenging environments.

FEATURES

• Filter connection: STANAG 4155 (EN 148-1) – Rd 40×1/7” threaded connection;
• Compatible masks: M21, C21 and IDEA CBRN full face masks;
• Weight: 170 g. ± 5%
• Dimensions: Height included thread 68mm, diameter 90mm;
• Shelf life: 5 years – 10 years vacuum sealed version;
• Materials: Resistant and anti-scratch high-quality ABS resin;
• Filtering materials: Activated carbon and filter paper;
• Packaging: Complete with 2 plastic covers, on both threaded connector and filter bottom. 1 piece, packed in a carton box 98mm x 98mm x 98mm;
• Conditions of storage: In original packaging: Temperature between -2°C and +55°C RH <75%;
• Marking:
›› Marking R means the filters can be used for more than one shift of work;
›› Marking D means the filter passed the clogging test with Dolomite dust and it has high performance in dusty and sandy settings;
• Limitations for use: Do not use in areas where the oxygen concentration is lower than 18% in volume nor in presence of gases different from those clearly indicated.

 

RIOT-C3 CS/CN/OC

The DPI Leonardo Riot-C3 Filter meets NIOSH 42CFR84 relevant criteria, ensuring optimal removal efficiency of CS/CN AGENTS and continuous 24-hour protection. With an A1B1E1K1P3-level combined filter element surpassing EN 14387 requirements, it achieves unparalleled performance, defending against OC (Pepper Spray), Organic TICs, Inorganic TICs, Acid TICs, Ammonia and Amine Gases, Dusts, Mists, Fumes, Biological Agents (including Bacteria, Viruses, and Fungal Spores), and
Radioactive Dusts. Tailored for Riot Control tactical operations, the Riot-C3 Filter seamlessly integrates with gas masks for a secure fit in today’s challenging environments.

FEATURES

• Filter connection: STANAG 4155 (EN 148-1) – Rd 40×1/7” threaded connection;
• Compatible masks: M21, C21 and IDEA CBRN full face masks;
• Weight: 190 g. ± 5%
• Dimensions: Height included thread 68mm, diameter 90mm;
• Shelf life: 5 years; 10 years vacuum sealed version;
• Materials: Resistant and anti-scratch high-quality ABS resin;
• Filtering materials: Activated carbon and filter paper;
• Packaging: Complete with 2 plastic covers, on both threaded connector and filter bottom. 1 piece, packed in a carton box 98mm x 98mm x 98mm;
• Conditions of storage: In original packaging: Temperature between -2°C and +55°C RH <75%.
• Marking:
›› Marking R means the filters can be used for more than one shift of work;
›› Marking D means the filter passed the clogging test with Dolomite dust and it has high performance in dusty and sandy settings;
• Limitations for use: Do not use in areas where the oxygen concentration is lower than 18% in volume nor in presence of gases different from those clearly indicated.